Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Nature of Source Flow: | Active Inverter |
| Certification: | CCC, ISO9001, RoHS, CE, SAA, FCC,ETL, SAA, CE, IATF 16949 |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency






Item | Description | Test condition | Nominal Value | Tolerance | Unit | Remark |
1 | "Electrical: Digital quantitative control, output in analog sine wave mode, providing high-efficiency output and strong load startup capability; equipped with input low voltage alarm, high and low voltage protection, automatic recovery, overload protection, short circuit protection, temperature protection and automatic recovery. Test conditions: Ambient temperature 20-25℃, humidity 40%-90%RH. Input DC 12.8V" | |||||
1.01 | MAX. Continuous Output Power | 600 | W | ≥1H | ||
1.02 | DC Input Static Current(No Load) | DC12.8V | ≤0.3 | A | ||
1.03 | Inverter Off | ≤20 | mA | |||
1.04 | Ac Output Wave Form | Modified Sine Wave | ||||
1.05 | High Voltage Cut Off Level | 15.5 | ±0.3 | V | During high-voltage protection, the buzzer keeps sounding, the green light goes out, the red light comes on, and there is no output. | |
1.06 | High Voltage Automatic Recovery | 14.5 | ±0.3 | V | ||
1.07 | Low Voltage Alarm | 10.5 | ±0.3 | V | When the low pressure alarm occurs, the indicator light turns green, the buzzer gives intermittent alarms, and there is still output. | |
1.08 | Low Voltage Cut Off Level | 10 | ±0.3 | V | During low-voltage protection, the buzzer keeps sounding, the green light goes out, the red light comes on, and there is no output. | |
1.09 | Low Voltage Automatic Recovery | 12 | ±0.3 | V | ||
1.1 | Output AC Voltage | 220 | +10/-20 | Vac | ||
1.11 | Output Frequency Level | 50 | ± 2 | HZ | ||
1.12 | Overload Power Range | 600 | +5%-+30% | W | When overloaded, the buzzer will continuously sound an alarm, the green light will go out, the red light will come on, and there will be no output. | |
1.13 | Temperature Protection | skin temperature | <65 | ℃ | When temperature protection is activated, the buzzer keeps sounding continuously, the green light goes out, the red light comes on, there is no output, and the fan operates normally. | |
1.14 | Temperature Recovery | NTC temperature | 50 | ±10 | ℃ | After the temperature protection is lifted, the NTC temperature should be within the range of 40-60℃. |
1.15 | USB Power Port OutputV/A(USB /) | 5 | ±0.25 | V | >1H,When the terminal is powered on, USB output is available. | |
3.1 | A | |||||
Tpey-C | QC2.0/3.0 | |||||
1.18 | Full Load Efficiency | ≥84 | % | |||
1.19 | Ac Output Short Circuit Protection(AC) | system shut down | During short-circuit protection, the buzzer keeps sounding continuously, the green light goes out, the red light comes on, there is no output, but no damage occurs. | |||
1.2 | Fan Run | (NTC location) | 50 | ±10 | ℃ | |
1.21 | Led Indicate | |||||
1.22 | Fuse (spade type) | 30 *3Pcs | A | |||
1.23 | Gnd Resistance | Output ground terminal to chassis screw | ≤1 | Ω | ||
1.24 | Input Reverse Polarity Protection | Short-circuit the fuse | Short-circuit the fuse | After replacing the fuse, everything returned to normal. | ||
1.25 | Led Indicate | Normal: Green Fault: Red | ||||
2.00 | Environmental requirement | |||||
2.01 | Operating temperature | 0-40 | ℃ | |||
2.02 | Operating Relative Humidity | 10-90 | % RH | |||
2.03 | Storage temperature | -10 - 50℃ | ℃ | |||
2.04 | Storage Relative Humidity | 10-95 | % RH | |||
2.05 | Size:195*104.5*64mm | |||||